Program External Page Directory Number Length:
•
Input
08-09-11-01
, then press [
save
].
•
Press [
chg
] until the appropriate length displays.
•
Press [
next
] to program Leading 1.
Program External Page Directory Number Leading 1, 2 or 3:
•
Input
08-09-11-02
, then press [
save
].
•
Press [
chg
].
•
Input the new directory number leading digit(s) (see Flexible Numbering Plan for rules of Directory
Numbers). Then press [
save
].
•
Press
the Hold button
to return to the previous menu level or press
the Volume button (up or down)
to
return to the DB Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
•
Use
¢£¤¥
to highlight “System Application.” Then press
«
.
•
Use
¢£¤¥
to highlight “Numbering Plan 4.” Then press
«
.
•
Use
¢£¤¥
to highlight the database item “External Pager – Length” if the length of this code is to be
changed.
•
Press
«
until the appropriate length displays.
Or…
•
Use
¢£¤¥
to highlight the directory number code that is to be changed, External Pager – Leading 1,
2 or 3.
•
Press
«
.
•
Input the new code and then press
«
to temporarily store this data.
See Flexible Numbering Plan for rules of directory number application.
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...