Loud Bell / External Page / Music Source – Control
There is often a requirement to control ancillary devices via the telephone system. The DX-80 system provides one
dry contact closure (standard) for interface of the various devices. It is important to adhere to the electrical
requirements of this contact. The contact closure is rated at 24vdc, 1Amp.
The Contact Closure can be assigned to operate in three different ways:
Loud Bell Control:
If the system is installed in high noise environments, there is often a requirement to equip a loud
(high-gain) ringing device. Using the contact in this way provides for control of an optional, ancillary loud ringing
device. The device is connected to the contact as a trigger. When ringing occurs on CO Lines in CO Line Groups
designated as Loud Bell CO Line Groups, the contact closure operates and controls the connected device.
External Page Control:
The contact may also be programmed to control External Paging apparatus. When
programmed in this manner, the contact closure operates whenever the External Paging Port is activated.
Music Source Control:
The contact may also be programmed to control Message On Hold devices. In this mode of
operation the contact closes (make) whenever CO lines are placed on Hold. This function can reduce wear on
electromechanical devices that provide the message on hold function.
Related Features
CO Line Ringing Modes
Music On Hold
External Paging
Related Programming
System Resource - Loud Bell
CO Line - CO Line Type, CO Line Group
Default Settings
System Resource – Loud Bell = “L.B.” (Loud Bell). (Range is: L.B., MS1, MS2, EP.)
System Resource – Loud Bell – CO Line Group – 1~8 = “N.” (Range is Y/N.)
Programming Abstract
•
Program the Loud Bell contacts for the device type control.
•
If using the contact for control of a Loud Bell device, program what CO Line Groups will activate the bell.
Programming via the DET (Digital Extension Terminal)
Note: [
back
], [
next
], [
show
], [
chg
], [
bksp
], and [
save
] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
•
Enter Database Administration using the feature code
!+*
and then enter the DB Admin password
“
++++++++
.” (Note: This eight-character password can be changed.)
•
Press [
show
]. The DB Item Select screen displays.
•
Input
04-13-1
, then press [
save
]. This advances to the Loud Bell – Application programming screen.
•
Press [
chg
] until the appropriate application displays (L.B., MS1, MS2, EP).
•
If the contact is to be used as LBC, press [
next
] to the CO Line Group(s) that will cause the contact to
operate.
•
Press [
chg
] to activate/deactivate the LBC for each CO Line Group.
•
Press
the Hold button
to return to the previous menu level or press the Volume button (up or down) to
return to the DB Item Selection screen or exit programming.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...