Copy CO Line(s) via Group (many at a time) programming method:
•
Use
¢£¤¥
to highlight “Group.” Then press
«
. The cursor is immediately positioned on the
Source CO Line Directory number input.
•
Input the CO Line directory number of the CO Line that has been programmed for copying to other CO
Lines.
•
Press
«
. The cursor immediately moves to the Destination Directory number input area.
•
Input the CO Line Group directory number (9, 800-806) where the copy data should be stored.
•
Press
«
. The cursor moves to the next input position allowing entry of the next CO Line Group
directory number. The previous entry remains displayed.
•
Continue inputting CO Line Group directory numbers for those CO Lines where the copy data should be
stored, pressing
«
after each input directory number.
•
When all CO Lines to be copied with the copy data have been input press the ESC (escape). At this
time it is possible to input another “Source” CO Line directory number and continue the process for
another group of CO Line(s).
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “Exit This Feature”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
CO Line Queuing / Callback
[
cbck
]
CO Line Queuing allows a user to request use of a busy CO line. When the CO Line goes idle (current user hangs
up), that CO Line rings the user that queued the line. While the line is ringing at the extension, it is unavailable for
access by other users. If the extension that queued the CO Line does not respond to the queue callback within 8
seconds, the queue is cancelled and the line becomes available for other users.
Related Features
CO Line Groups
Related Programming
CO Line – CO Group
Extension – Line Assignment
Operation – Queue
1. Press a CO Line that is busy or dial access to a CO Line Group (9, 800-806).
The display shows:
CO LN BUSY XXX
cbck
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...