DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-14
Program Alternate Attendant Extension
•
Return to the Database Item Select screen by pressing the Volume button (up or down).
•
Enter
04-02-1-06
to program the attendant extension for Tenant Group 1. (
04-02-2-06
for Tenant 2 Group;
04-02-3-06
for Tenant Group 3.)
•
Press [
save
].
•
To change the designated attendant extension press [
chg
] (change).
•
Enter the extension number to be assigned as the Attendant Extension.
Note: Only valid extension directory numbers can be assigned as tenant group attendants. Extensions
that are programmed as Attendant for another Tenant Group or Alternate Attendant cannot be
programmed as the attendant.)
•
Press [
save
].
Program Attendant Extension Password
•
Reference “Attendant Extension” for programming instructions of this feature. The default password is 9999.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then press
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select “Programming” from the PC-DBA menu.
Program Attendant Extension
•
Use
¢£¤¥
to highlight “System Resource” and then press
«
.
•
The cursor is now positioned on the database item - “Attendant.”
•
Press
«
. The cursor is now positioned on the database item “Attendant - Tenant 1.”
•
Press
«
to select this data item for change. The data item is ready for input.
•
Enter the extension directory number to be assigned as the Attendant Extension.
•
Press
«
continue.
Program Alternate Attendant Extension
•
Use
¢
to highlight Alternate Attendant database item.
•
Press
«
to select this data item for change. The data item is ready for input.
•
Enter the extension directory number to be assigned as the Alternate Attendant Extension.
•
Press
«
.
•
Use
¢£¤¥
to highlight the next database item to be changed and follow the conventions used in the
previous steps to complete any other changes required.
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...