Programming via the DET (Digital Extension Terminal)
Note: [
back
], [
next
], [
show
], [
chg
], [
bksp
], and [
save
] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
•
Enter Database Administration using the feature code
!+*
and then enter the DB Admin password
“
++++++++
.” (Note: This eight-character password can be changed.)
•
Press [
show
]. The DB Item Select screen displays.
•
Input
02-740~755-10
, then press [
save
]. This advances to the Private To programming for the CO Line
selected.
•
Press [
chg
].
•
Input the extension number where this CO Line is to be assigned as private.
•
Press
the Hold button
to return to the previous menu level or press
the Volume button
to return to the DB
Item Selection screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
•
Use
¢£¤¥
to highlight “CO Line” and then press
«
.
•
Use
¢£¤¥
to highlight “Category 1” Then press
«
.
•
Use the cursor arrows to highlight the database item “Private To” for the CO Line to be changed.
•
Press
«
.
•
Input the extension directory number of the extension that this CO Line is to be assigned as private.
•
Press
«
to temporarily store this data.
•
Continue making other programming changes as required.
•
When all changes are made press the
°
(escape) key to exit this database-programming screen. You will
see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a
“
SEND
”
function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...