DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-224
•
Use the cursor arrows to highlight “Category 2” and then press Enter.
•
Use the cursor arrows to highlight the database item “SMDR Output” for the Extension to be changed.
(Note: You may need to use the Page Up/Down keys to view the extension for which changes are
required.)
•
Press Enter. Each time that enter is pressed the value of this database item is updated.
•
When all changes are made press the ESC (escape) key to exit this database-programming screen.
You will see the prompt: “Exit This Feature”; press “
Y
” for yes.
•
You will then be prompted to “Save Current Setting?”
Ø
Press “
N
” to abort changes and leave all data unchanged.
Ø
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “File Exists, Override?”
Ø
Press “
N
” to abort changes and leave all data unchanged.
Ø
Press “
Y
” (yes) to continue with the save operation.
•
Press ESC (escape) again to return to the Database Programming menu.
•
To program call logging conditions (Outgoing/Incoming/Account Code):
•
Use the cursor positioning arrows to highlight “Call Handling” and then press Enter.
•
Use the cursor arrows to highlight “Category 2” and then press Enter.
•
Use the cursor arrows to highlight the database item “SMDR Call Output – Outgoing/Incoming/Account
Code” as required.
•
Press Enter. Each time that enter is pressed the value of this database item is updated.
•
Continue to make other changes to the Call Output settings as required.
•
When all changes are made press the ESC (escape) key to exit this database-programming screen.
When you will see the “Exit This Feature?” prompt, press “
Y
” for yes.
•
You will then be prompted to “Save Current Setting?”
Ø
Press “
N
” to abort changes and leave all data unchanged.
Ø
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “File Exists, Override?”
Ø
Press “
N
” to abort changes and leave all data unchanged.
Ø
Press “
Y
” (yes) to continue with the save operation.
•
Press ESC (escape) again to return to the Database Programming menu.
•
To program the (CIL) Call Information Log serial port baud rate (CIL X_RATE):
•
Use the cursor positioning arrows to highlight “System Resource” and then press Enter.
•
Use the cursor arrows to highlight “Modem & Serial Port” and then press Enter.
•
Use the cursor arrows to highlight the database item “CIL X_Rate.”
•
Press Enter. Each time that enter is pressed the value of this database item is updated.
•
When all changes are made press the ESC (escape) key to exit this database-programming screen.
You will see the prompt: “Exit This Feature”; press “
Y
” for yes.
•
You will then be prompted to “Save Current Setting?”
Ø
Press “
N
” to abort changes and leave all data unchanged.
Ø
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “File Exists, Override?”
Ø
Press “
N
” to abort changes and leave all data unchanged.
Ø
Press “
Y
” (yes) to continue with the save operation.
•
Press ESC (escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...