DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
4-24
SW/HW Revision
SW/HW Revision can be invoked to view the current version of software installed in the DX-80. The
Hardware Revision (HW Revision) is a label only field that allows the user of PC-DBA to record the
revision of hardware installed at the site. This information is stored in the Database Save operation of PC-
DBA.
+--------------------------------- DX80 PC-DBA --------------------------------+
¦ [Cnt] KSU Revision : K16UM0.F19 Date: 01/02/14 ¦
¦ Time: 20:55:05 ¦
¦ Maintenance - SW/HW Revision : ¦
¦ ¦
¦ BOARD POS SW Revision HW Revision ¦
¦ CPM BOARD K16UM0.F19 NULL ¦
¦ 8VM CARD POMVM0.F01 NULL ¦
¦ MDM CARD NULL NULL ¦
¦ DPM BOARD 1/01 PEDUM0.F09 NULL ¦
¦ OPEN 1/02 NULL NULL ¦
¦ OPEN 1/03 NULL NULL ¦
¦ APM4 BOARD 1/04 PEAUM0.F09 NULL ¦
¦ OPEN 2/01 NULL NULL ¦
¦ OPEN 2/02 NULL NULL ¦
¦ OPEN 2/03 NULL NULL ¦
¦ OPEN 2/04 NULL NULL ¦
¦ COM BOARD 1/1&5 PTLUM0.F09 NULL ¦
¦ OPEN 2/1&5 NULL NULL ¦
¦ ¦
¦ ¦
¦ ¦
+----------------------------------- R16UM0.F21 -------------------------------+
Event
The Event tracking operation can be invoked to record system actions processed for the purposes of
debugging the system. This operation is rarely required and usually invoked following a request by the
customer service department to do so.
Event tracking can be started by a specified system operation and programmed to end output of
processed data by a specific system operation or never to end until manually forced to discontinue. To
start event tracking use Event Invoking and select one of the available system operations that will cause
event data output to begin. (Do not select “Pseudo” to begin event tracking. This operation is a non-
occurring event intended for use with “End Event” when the event output should not end by a system
operation.)
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...