DX-80 I
NSTALLATION AND
M
AINTENANCE
M
ANUAL
P7290 IMM
3-72
Program Call Abandon Timers as required, to match CO operation. (03-41 and 03-42):
•
At the DB Item Select screen input
03-41
for
Talk Abandon
(Call Abandon during conversation “talk” mode.)
Or…
•
03-42
for
Hold Abandon
(Call Abandon during on hold mode.)
•
Press [
chg
].
•
Input the value for this database item. (Accepted entries are 50-1000, in increments of 50 milliseconds.)
•
Press [
save
].
•
To select the previous or next database item, press [
back
] or [
next
].
•
When finished programming Call Abandon database items, press
the Volume button
(up or down) to
return to the DB Item Select screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
Program CO Lines for Call Abandon:
•
Use
¢£¤¥
to highlight “CO Line.” Then press
«
.
•
Use
¢£¤¥
to highlight “Category 1.” Then press
«
. (Notice the display header “CO Line Category
1 : [1/2].” The “[1/2],” indicates that this is the first of two pages for this database programming. Page 1
shows the programmable database items for CO Line ports 1-8 (CO Lines 740-747).)
•
Use the
³
and
´
buttons on the PC keyboard to select the screen of Category 1 that show the CO
Line(s) to be programmed.
•
Use
¢£¤¥
to highlight Call Abandon for the appropriate CO Line. (CO Lines are listed along the left
side of the display.)
•
Press
«
until the appropriate value displays.
•
Continue programming other database items as required.
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...