Program extensions for the ability to Receive (answer) CO Lines while ringing.
(01-xxx-24-cc):
•
Input
01-xxx-24-cc
(where “xxx” = extension to be programmed and “cc” = CO Line number {01-16} to be
programmed).
•
Press [
save
]. This advances to the Receive Assignment for the extension and specific CO Line selected.
•
Press [
chg
] until the appropriate value displays. (Y/N)
•
Press [back or [next] to go to the previous or advance to the next CO Line to program for this extension.
Or…
•
Press
the Volume button
(up or down) to return to the DB Item Select screen and input the next
extension/CO Line to program.
•
When all changes are complete, press
the Volume button
(up or down) to return to the DB Item Select
screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing “DX-80” at the DOS prompt in the PC-DBA working directory and then pressing
«
.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
•
Use
¢£¤¥
to highlight “Extension.” Then press
«
.
•
Use
¢£¤¥
to highlight “Receive Assignment.” Then press
«
.
•
Use
¢£¤¥
and
³´
to highlight the extension and CO Line to change.
•
Press
«
until the appropriate data displays. (Y/N)
•
Use
¢£¤¥
and
³´
to highlight the next extension/CO Line to change.
•
Continue this process for all extensions/CO Lines to change.
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...