Port located on the 408M that is connected to the first CO Line circuit. Whenever power fails this port
becomes active with dial tone from the CO line connected to the first CO line port.
The 408M is equipped with a Heart-beat LED that indicates processing activity on the PCB. (The 408M
peripheral processor is operating when the Heartbeat LED is flashing.) The KSU1 operation LED (located
next to the power switch) is tied to the 408M Heartbeat LED. Therefore, when the LED next to the power
switch is flashing, the 408M is active.
The KSU1-408M has three ribbon cables; one at the upper right and oriented in a horizontal position (J1) is
used to interface a COM4 if required to expand the system CO Line capacity. The other two ribbon cables
located at the upper center and oriented in a vertical position. J4 is used to interface the DX-80 CPM. J5
connects to the standard APM4 installed in KSU1.
Each CO line circuit incorporates over-voltage protection, ring detector, loop detector, loop/pulse-dial relay,
current sink circuit, coupling/isolation transformer (impedance 600:600), hybrid circuit, CODEC & filter,
polarity guard circuit and Radio Frequency noise filter.
Figure 3: KSU1 shown with cover – CPM and APM4 removed (408M exposed)
The fourth CO Line port is equipped with CNG Fax Tone Detection circuitry. When programmed as a “FAX”
line, this circuit will automatically engage the FAX Tone detector. If FAX tone is detected, the call is routed to
the analog port designated as the destination for fax calls.
Each digital port (connects to Digital Executive Telephones and DSS Consoles) is comprised of a
proprietary octal ASIC (Application Specific Integrated Circuit) transceiver. There are three data channels in
operation at each digital port via the octal transceiver. One channel is used for call processing control of
digital terminal functions/operations and two channels are used for the digital voice channel requirements.
Each digital station interface is protected against circuit wiring shorts by an over-current protection
Polyswitch. The digital station circuit requires only one cable pair to operate and is not polarity sensitive.
Physical connection of digital extensions, power failure telephones and CO lines to the 408M module is
made through convenient RJ-11 connectors along the bottom edge of the module.
408E
The 408E is very similar to the 408M; however, it is unique to KSU2. The 408E (KSU2 component) provides
interface for up to 4 loop-start CO Lines and 8 Digital Extension Ports. Additionally the 408E regulates the
24 volt DC power from the source to produce all required logic voltages and operations voltages. There is
also a Power Failure Port located on the 408E that is associated to the first CO Line circuit. Whenever
power fails this port becomes active with dial tone from the CO line connected to the first CO line port.
Power
Failure
port
Four Loop
Start CO
Line ports
COM4
ribbon
cable
CPM
ribbon
cable
APM4
ribbon
cable
Eight
digital
ports
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...