Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press
«
.
•
Use
¢£¤¥
to highlight “Extension.” Then press
«
.
•
Use
¢£¤¥
to highlight “Category 1.” Then press
«
.
•
Use
¢£¤¥
,
³´
to highlight the database item “Pickup Group” for the Extension to be changed.
•
Press
«
.
Each time that enter is pressed the value of this database item is updated.
•
When you have completed all changes, press the
°
(escape) key to exit this database programming
screen. You will see the prompt: “
Exit This Feature
”; press “
Y
” for yes.
•
You will then be prompted to “
Save Current Setting
?”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” to save changes.
•
If you press “
Y
” (yes), you will then be prompted “
File Exists, Override?
”
•
Press “
N
” to abort changes and leave all data unchanged.
•
Press “
Y
” (yes) to continue with the save operation.
•
Press
°
(escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a “SEND” function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
Extension Programming Copy
This database feature is used to copy the various extension programming settings quickly from one extension to
other extensions. There are two methods to copy extension data to other extensions: 1) “individual” is used to copy
from the source extension to other extensions, one at a time; 2) “group” is used to copy from the source extension to
other extensions, using the Pick Up Group to identify the extensions that will receive the copy as a group.
Related Programming
System Application - Extension Copy, Feature Key Copy, CO Line Copy, DSS Copy
Conditions
a) The source extension must have all programming changes completed prior to invoking a copy.
b) When using Group Copy, all extensions to receive the copy must be programmed for the correct Pick Up
Group to associate them with other extensions to receive this copy.
Programming Abstract
Use Extension Programming Copy to copy the programmed settings of one extension to one other extension
or to a group of extensions.
Programming via the DET (Digital Extension Terminal)
Note: [
back
], [
next
], [
show
], [
chg
], [
bksp
], and [
save
] are LCD interactive button operations. Use the
three buttons below the LCD display to actuate the associated operation.
•
Enter Database Administration using the feature code
!+*
and then enter the DB Admin password
“
++++++++
.” (Note: This eight-character password can be changed.)
•
Press [
show
]. The DB Item Select screen displays.
Содержание DX-80
Страница 1: ...C O M D I A L D X 8 0 DX 80TM Installation Maintenance Manual ...
Страница 10: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM TOC 6 ...
Страница 50: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 2 20 ...
Страница 316: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 3 266 ...
Страница 346: ...DX 80 INSTALLATION AND MAINTENANCE MANUAL P7290 IMM 4 30 ...