Chapter 46: Command Line Descriptions
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
3069
trace logging packetcable pcmm
Purpose
Enables all DQoS gate trace, event messaging, and all modem (except BPI and ranging) logging for a single customer as specified
by the customer’s MTA IP address.
Default Access Level
15
Command Syntax
trace logging packetcable pcmm <ip>
trace logging packetcable pcmm <ip> no
Supplemental
Information
To disable logging, use the no option.
Parameters
<ip>
Use either the IPV4 or IPV6 address.