Chapter 9: Upstream Cable Access Modules (UCAMs)
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
297
attribute-mask - Configure attributes for this channel for channel assignment
cable-mac - Assign an upstream to a specific cable mac
channel-id - Provision the channel identifier for the upstream
channel-width - Provision the channel-width for an upstream
connector - Provision the connector for an upstream
databackoff - databackoff <WORD>
docsis-mode - Provision the docsis mode for an upstream
frequency - Provision the frequency for an upstream
ingress-cancellation - Upstream ingress cancellation properties
load-balance - Turn on/off dynamic load balancing for the upstream channel
map-size - Provision the map size for an upstream
max-power-adj - Provision the max power adjust for an upstream
mini-slot-size - Provision the mini slot size for an upstream
modulation-profile - Provision the modulation profile for an upstream
num-equalizer-taps -
Set the number of taps in the receiver’s equalizer
power-level - Provision the power level for an upstream
pre-eq-enable - Use pre-equalization technique to reduce upstream signal distortion
rangebackoff - rangebackoff <WORD>
relay-agent-option - Relay agent circuit ID sub-option
scdma - Upstream SCDMA properties
show - Display the upstream configuration
spectrum-group - Enables frequency agility on this port
supervision - Provision the supervisory downstream for this upstream.
threshold-power-offset - Provision the power offset threshold for an upstream
voice-limits - Set voice data limits
9.
Refer to the
(page 1127) for additional information on this command.
10.
Repeat this procedure as needed for the remaining US ports, 0–11 (12U CAM) or 0-23 (24U CAM), on this CAM.
Putting Cards and Ports into Service
This procedure assumes that the US and DS channels have already been configured. This example is for a 24U CAM:
1.
The following command brings the CAM online:
configure slot <slot> no shutdown
Where: slot = the number of the slot, 0-15.
2.
Bring up the upstream channel:
configure interface cable-upstream <slot>/<port> no shutdown
3.
Bring up the logical channel:
configure interface cable-upstream <slot>/<port[.0]> no shutdown