Chapter 46: Command Line Descriptions
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
1711
configure interface cable-upstream * cable num-equalizer-taps
Purpose
Sets the number of taps in the receiver’s equalizer.
Default Access Level
15
Command Syntax
configure interface cable-upstream <slot/ch[.0]> cable num-equalizer-taps <5 | 24>
Supplemental
Information
The value for the number of equalizer taps is set on a logical channel basis. The default setting of 24 is recommended for most RF
plants in the field. In low noise and lab upstream RF plants, signal-to-noise ratios might be slightly improved by setting the number
of equalizer taps to 5.
Parameters
<slot/ch[.0]>
The upstream slot/channel[.logical channel]. It will assume lc=0 if needed and not supplied.
<5 | 24>
Number of taps in the receiver’s equalizer. Default value is 24 taps.