Chapter 14: Cable-side Configuration
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
423
show cable fiber-node detail
An output similar to the following example will occur:
Cable mDSsg/
Fiber Node MAC mCMsg mUSsg
Ports
------------- ----- ----- ------ --------------------
FN1
1
2
U1
1/0.0 1/1.0 1/2.0
FN1
1
2
D1
14/0 14/1 14/2 14/3
FN2
2
3
U1
1/3.0 1/4.0 1/5.0
FN2
2
3
D1
14/4 14/5 14/6 14/7
FN3
3
4
U1
1/6.0 1/7.0 1/8.0
FN3
3
4
D1
14/8 14/9 14/10 14/11
FN4
4
5
U1 1/9.0 1/10.0 1/11.0
FN4
4
5
D1
14/12 14/13 14/14 14/15
* Indicates that downstream channel is not primary-capable.
Display Specific MAC Domain Fiber Nodes
The following command example displays detailed information regarding specific MAC domain fiber nodes and their
associated service groups and ports:
show cable fiber-node cable-mac 1
An output similar to the following example will occur:
Cable mDSsg/
Fiber Node MAC mCMsg mUSsg Ports
---------------- ----- ----- ------ ---------------------------------------
FN1 1 1 U1 3/0 3/1 3/2 3/3
FN1 1 1 D1 12/0 12/1 12/2 12/3
* Indicates that downstream channel is not primary-capable.
Display Specific MD-CM-SG Fiber Nodes
The following command example displays detailed information regarding specific MAC domain CM signaling group fiber
nodes and their associated service groups and ports:
show cable fiber-node mCMsg 1