Chapter 9: Upstream Cable Access Modules (UCAMs)
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
287
Purpose
CLI Command
Assign a channel to cable-mac 1
configure interface cable-upstream 5/0 cable cable-
mac 1
Configure the Upstream Frequencies and Connectors
Assign upstream channel 0 of CAM 5, to connector 0.
configure interface cable-upstream 5/0 cable
connector 0
Configure upstream channel 0 of CAM 5, to use frequency 12
MHz.
configure interface cable-upstream 5/0 cable
frequency 12000000
Specify that DS channel 14/0 carries the supervision for channel
5/0.
configure interface cable-upstream 5/0 cable
supervision 14/0
Put CAM in Service
Restore upstream channel 0 of CAM 5 to service.
configure interface cable-upstream 5/0 no shutdown
Restore the logical channel to service.
configure interface cable-upstream 5/0.0 no
shutdown
Confirm channel settings for slot 5.
show interface cable-upstream 5
To view the channel settings resulting from configuring the 24U CAM (note that this example shows that a downstream
was previously configured), enter:
show interface cable-upstream 5
Upstream Port 5/0
-------------
Port state: IS
Connector: 0
Cable-Mac: 1
Downstream Supervision Ports: 14/0
Frequency (Hz): 12000000
Channel width (Hz): 3200000
Equalizer Coefficient State: off
Power (dBmV): 0
Max Power Adj Per Range Resp (1/4 dBmV): 24
Ranging Power Thresh For Success (1/4 dBmV): 24