Chapter 14: Cable-side Configuration
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
420
Display Upstream Channel Sets
The following command example displays all upstream channel sets:
show cable channel-sets us
An output similar to the following example will occur:
Cable
-mac chSetId DS/US Channel Set
----- ---------- ----- ----------------------------------------
1 0x00000100 US 1/4 1/5 1/6 1/7
2 0x00000100 US 1/8 1/9 1/10 1/11
3 0x00000100 US 2/0 2/1 2/2 2/3
3 0x01000002 US 2/0 2/1 2/2 2/3
4 0x00000100 US 2/4 2/5 2/6 2/7
4 0x01000001 US 2/4 2/5 2/6 2/7
5 0x00000100 US 2/8 2/9 2/10 2/11
5 0x01000001 US 2/8 2/9 2/10 2/11
6 0x00000100 US 4/0 4/1 4/2 4/3
6 0x01000002 US 4/0 4/1 4/2 4/3
Display Specific MAC Domain Channel Sets
The following command example displays a specific MAC domain channel set:
show cable channel-sets cable-mac 1
An output similar to the following example will occur:
Cable
-mac chSetId DS/US Channel Set
----- --------- -------- -----------------------------------------------
1 0x00000100 DS 13/0 13/1 13/2 13/3
1 0x00000100 US 1/4 1/5 1/6 1/7
Display Specific Channel Set ID
The following command example displays a specific channel set ID:
show cable channel-sets channel-set-id 0x01000001
An output similar to the following example will occur: