Chapter 46: Command Line Descriptions
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
1801
configure interface gigabitethernet * ipv6 nd reachable-time
Purpose
Sets the amount of time the neighbor is considered "reachable" after the last confirmation.
Default Access Level
15
Command Syntax
configure interface gigabitethernet <slot>/<port>[.<0-254>] ipv6 nd reachable-time <0-3600000>
configure interface gigabitethernet <slot>/<port>[.<0-254>] ipv6 nd reachable-time [<0-3600000>] no
Supplemental
Information
To return to the default, use the no option.
Parameters
<slot>/<port>[.<0-
254>]
RCM slot number/gigabitEthernet port number[.subinterface number].
Valid range for the C4 CMTS is <17-18>/<0-9>[.<0-254>]
Valid range for the C4c CMTS is <17>/<0-9>[.<0-254>]
<0-3600000>
Time in milliseconds.