Chapter 12: Basic Bring-up Procedure for a C4c CMTS
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
369
Sync interval (milliseconds): 10
UCD interval (milliseconds): 1600
Ranging Cycles Int (centiseconds): 120
TFTP Enforcement: disabled
Dynamic Secret: disabled
Insertion interval (centiseconds): 40
Invited ranging attempts: 16
Fibernode(s): FN1, FN2, FN3, FN4
RCP-id: 0010000005 RCC: dyn
Module: 1 MinCFreq:621000000 ModConnID:0
CM-chan Downstream Frequency Primary
1 15/0 621000000 Primary
2 15/1 627000000 Capable
3 15/2 633000000 Capable
4 15/3 639000000 Capable
To display the supervisory downstream for the upstream channels, enter:
show cable supervision
An example of the show interface cable supervision output:
C4# show cable supervision
MAC US DS Method
----- ------- ----- -----------
1 10/0.0 15/0 Provisioned
1 10/0.0 15/1 Provisioned
1 10/0.0 15/2 Provisioned
1 10/0.0 15/3 Provisioned
1 10/1.0 15/0 Provisioned
1 10/1.0 15/1 Provisioned
1 10/1.0 15/2 Provisioned
1 10/1.0 15/3 Provisioned
1 10/2.0 15/0 Provisioned
1 10/2.0 15/1 Provisioned
1 10/2.0 15/2 Provisioned
1 10/2.0 15/3 Provisioned
1 10/3.0 15/0 Provisioned
1 10/3.0 15/1 Provisioned
1 10/3.0 15/2 Provisioned
1 10/3.0 15/3 Provisioned