Chapter 22: Channel Bonding
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
693
7.
Assign the four upstreams to physical connectors:
configure interface cable-upstream 1/0 cable connector 0
configure interface cable-upstream 1/1 cable connector 0
configure interface cable-upstream 1/2 cable connector 1
configure interface cable-upstream 1/3 cable connector 1
8.
Set the upstream center frequencies:
configure interface cable-upstream 1/0 cable frequency 20000000
configure interface cable-upstream 1/1 cable frequency 25000000
configure interface cable-upstream 1/2 cable frequency 20000000
configure interface cable-upstream 1/3 cable frequency 25000000
9.
Assign downstream supervision to each of the four upstream channels:
configure interface cable-upstream 1/0 cable supervision 14/0
configure interface cable-upstream 1/0 cable supervision 14/1
configure interface cable-upstream 1/0 cable supervision 14/2
configure interface cable-upstream 1/0 cable supervision 14/3
configure interface cable-upstream 1/1 cable supervision 14/0
configure interface cable-upstream 1/1 cable supervision 14/1
configure interface cable-upstream 1/1 cable supervision 14/2
configure interface cable-upstream 1/1 cable supervision 14/3
configure interface cable-upstream 1/2 cable supervision 14/0
configure interface cable-upstream 1/2 cable supervision 14/1
configure interface cable-upstream 1/2 cable supervision 14/2
configure interface cable-upstream 1/2 cable supervision 14/3
configure interface cable-upstream 1/3 cable supervision 14/0
configure interface cable-upstream 1/3 cable supervision 14/1
configure interface cable-upstream 1/3 cable supervision 14/2
configure interface cable-upstream 1/3 cable supervision 14/3
10.
In this example use the default modulation profile, which is mod profile number 2. Assign modulation profile number 2
to the upstream channels:
configure interface cable-upstream 1/0.0 cable modulation-profile 2
configure interface cable-upstream 1/1.0 cable modulation-profile 2
configure interface cable-upstream 1/2.0 cable modulation-profile 2
configure interface cable-upstream 1/3.0 cable modulation-profile 2