configure interface cable-downstream * cable dsg timer-list
Purpose
Associates the timers to be included in the DCD message that is sent down the specified interface.
Default Access Level
15
Command Syntax
configure interface cable-downstream
<slot/port>
cable dsg timer-list <timersetindex>
configure interface cable-downstream
<slot/port>
cable dsg timer-list [<timersetindex>] no
Supplemental
Information
To remove the association, use the no option
Parameters
<slot>
The chassis slot in which the targeted downstream Cable Access Module resides. Valid range for the C4 CMTS is 0-15; valid range for
the C4c CMTS is 10-15.
<port>
The downstream port.
<timersetindex>
A decimal integer index corresponding tdsgIfDownTimerIndex for a row in the dsgIfTimerTable. There must be at least one row in
the dsgIfTimerTable with a dsgIfTimerIndex equal to timerSetIndex for this command to succeed.