Chapter 46: Command Line Descriptions
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
1260
configure cable dsg timer-list
Purpose
Creates the configuration of DSG timers that will be associated with a given downstream channel.
Default Access Level
15
Command Syntax
configure cable dsg timer-list <0-4292967295> [initialization-tdsg1 <1-65535>] [operational-tdsg2 <1-
65535>] [two-way-tdsg3 <0-65535>] [one-way-tdsg4 <0-65535>]
configure cable dsg timer-list <0-4292967295> [initialization-tdsg1 <1-65535>] [operational-tdsg2 <1-
65535>] [two-way-tdsg3 <0-65535>] [one-way-tdsg4 <0-65535>] no
Supplemental
Information
To remove the timer-list entry, use the no option.
Parameters
<0-4292967295>
The index for a set of DSG timers.
[initialization-tdsg1
<1-65535>]
Timeout period for the DSG packets during initiation of the DSG client in seconds. Valid range is 1-65535 and the default is set at 2
seconds.
[operational-tdsg2
<1-65535>]
Timeout period for the DSG packets during normal operation of the DSG client in seconds. Valid range is 1-65535 and the default is
set at 600 seconds (10 minutes).
[two-way-tdsg3
<0-65535>]
This timer determines when the client attempts to reconnect with the DSG agent and establish two-way connectivity. Valid range is
0-65535 and the default is set at 300 seconds (5 minutes).
[one-way-tdsg4
<0-65535>]
This timer determines when the client attempts to rescan for a DOCSIS downstream channel that contains DSG packets. Valid range
is 0-65535 and the default is set at 1800 seconds (30 minutes).