Chapter 46: Command Line Descriptions
STANDARD Revision 1.0
C4® CMTS Release 8.3 User Guide
© 2016 ARRIS Enterprises LLC. All Rights Reserved.
1363
configure cable load-interval
Purpose
Configures the interval for utilization calculations.
Default Access Level
15
Command Syntax
configure cable load-interval <300-86400>
configure cable load-interval no
Supplemental
Information
Note: Changes to the cable load-interval are not immediate and will take effect after the current interval has expired.
WARNING: On large systems, setting this value to low will drain CPU resources. The minimum recommended value is 300 seconds.
To disable the interval used for utilization calculations, use the no option
Parameters
<300-86400>
The interval in seconds to collect/compute utilization data.