E6581611
M-4
13
(Continued)
Error code
Failure code
Problem
Possible causes
Remedies
The motor parameter
,
,
,
,
are not set correctly.
Set the left column parameters correctly
as a motor name plate and make an auto-
tuning again.
Set parameter
f416
to smaller 70% of
the present value, and execute the auto-
tuning again.
The motor with the capacity of 2 classes
or less than the inverter is used.
The output cable is too thin.
The inverter is used for loads other than
those of three-phase induction motors.
Set the left column parameters correctly
as a motor name plate and make an auto-
tuning again.
Then set
f400
=
1
, when trip occurs.
The motor is not connected.
Connect the motor.
Check whether the secondary magnetic
contactor.
The motor is rotating.
Make an auto-tuning again after the
rotation of the motor stops.
0028
0054
0055
0056
Auto-tuning error
Parameter
pt
=
6
is set and High speed
motor is connected.
Choose the higher power range drive.
(1 class up drive is recommended.)
A ground fault occurs in the output cable
or the motor.
Check the cable and the motor for ground
faults.
Overcurrent of dynamic braking resistor
Increase the deceleration time
dec
.
Set the supply voltage correction
f307
to
1
or
3
.
0022 Ground
fault
When inverters are fed by AC power
supply and connected with common DC
bus link, unnecessary trip occurs.
Set the parameter
f614
to
0
“Disabled”.
*
002F
Step-out (for PM
motor drive only)
The motor shaft is locked.
One output phase is open.
An impact load is applied.
Using the DC braking function.
Unlock the motor shaft.
Check the interconnect cables between
the inverter and the motor.
Prolong the acceleration / deceleration
time.
Turn off the Step-out function when using
the DC braking function or change the DC
braking to Servo lock function.
0029 Inverter
type
error
It may be a breakdown failure.
Contact your Toshiba distributor.
002D
Over speed fault
The input voltage fluctuates abnormally.
Over speed fault due to the overvoltage
limit operation.
Check the input voltage.
Install an optional dynamic braking
resistor. (optional)
*
0032
Analog input break
detection fault
The input signal from VIC is equal to or
less than the
setting.
Check the VIC signal cable for breaks.
Also, check the input signal value or
setting of
.
0033 CPU
communications
error
A communications error occurs between
control CPUs.
Contact your Toshiba distributor.
0034 Over
torque
boost
fault
The automatic torque boost parameter
setting is too high.
The motor has too small impedance.
Set a lower automatic torque boost
parameter
setting.
Make an auto-tuning.
0035 CPU
fault
2
The control CPU is defective.
Contact your Toshiba distributor.
0037
Optional unit fault 2
An optional device is defective.
Contact your Toshiba distributor.
003A CPU
fault
3
The control CPU is defective.
Contact your Toshiba distributor.
0057
Internal circuit fault
Internal circuit is defective.
Contact your Toshiba distributor.
0040 PTC
fault
PTC thermal protection is occurred.
Check the PTC in motor.
0045 Servo
lock
fault
The motor shaft is not locked in servo lock
operation.
Reduce the load in servo lock operation.
* This marking trips can be selected valid or invalid by parameters.
(Continued overleaf)