E6581611
K-18
11
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
0627 Undervoltage
trip/alarm
selection
-
-
0: Alarm only(detection level 60% or less)
1: Tripping (detection level 60% or less)
2: Alarm only(detection level 50% or
less, inputAC reactor required)
3: -
0
6.29.13
0629 Factory
specific
coefficient 6B
- -
-
-
* 3
0631 Inverter
overload
detection method
-
-
0: 150%-60s (120%-60s)
1: Temperature estimation
0 5.6
0632 Electronic-thermal
memory
-
-
0: Disabled (
thr
,
f173
)
1: Enabled (
thr
,
f173
)
2: Disabled (
thr
)
3: Enabled (
thr
)
0 5.6
6.29.1
0633
Analog input break
detection level (VIC)
%
1/1
0: Disabled,
1-100
0
6.29.14
0634 Annual
average
ambient
temperature (parts
replacement
alarms)
-
-
1: -10 to +10
C
2: 11-20
C
3: 21-30
C
4: 31-40
C
5: 41-50
C
6: 51-60
C
3
6.29.15
0643
Factory specific
coefficient 6C
- -
-
- *
3
0644
Operation
selection of
analog input break
detection (VIC)
- -
0:
Tripping
1: Alarm only (Coast stop)
2: Alarm only (
f649
frequency)
3: Alarm only (Maintain running)
4: Alarm only (Deceleration stop)
0
6.29.14
0645
PTC thermal
selection
- -
1:
Tripping
2: Alarm only
1
6.29.16
0646
PTC detection
resistor value
Ω
1/1
100-9999 3000
0648
Number of starting
alarm
10000
times
0.1/0.1
0.0-999.0
999.0
6.29.17
0649
Fallback frequency
Hz 0.1/0.01
ll
-
0.0
6.29.14
0650 Forced
fire-speed
control selection
- -
0:
Disabled
1: Enabled
0
6.30
0656
Factory specific
coefficient 6D
- -
-
- *
3
0657 Overload
alarm
level
% 1/1
10-100
50
5.6
0660 Override
addition
input selection
- -
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4:
fc
0
6.31
0661 Override
multiplication input
selection
- -
0: Disabled
1: Terminal VIA
2: Terminal VIB
3: Terminal VIC
4:
f729
0
0663 Analog
input
terminal function
selection (VIB)
-
-
0: Frequency command
1: Acceleration/deceleration time
2: Upper limit frequency
3, 4: -
5: Torque boost value
6: Stall prevention level
7: Motor electronic-thermal protection
level
8 to 10: -
11: Base frequency
0
6.32
*2: Default setting values vary depending on the capacity. Refer to section 11.4.
*3: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.