E6581611
F-57
6
[500V class]
In case of
aul
=
1
(constant torque characteristic (150%-60s) setting)
(480V or less)
PWM carrier frequency
VFS15-
Ambient
temperature
2.0k
~
4.0kHz 4.1k
~
12.0kHz 12.1k
~
16.0kHz
40
°
C or less
1.5 A
1.5 A
1.5 A
40
∼
50
°
C
1.5 A
1.5 A
1.5 A
4004 PL-W
50
∼
60
°
C
1.4 A
1.2 A
1.2 A
40
°
C or less
2.3 A
2.1 A
2.1 A
40
∼
50
°
C
2.3 A
2.1 A
2.1 A
4007 PL-W
50
∼
60
°
C
2.2 A
1.7 A
1.7 A
40
°
C or less
4.1 A
3.7 A
3.3 A
40
∼
50
°
C
4.1 A
3.7 A
3.3 A
4015 PL-W
50
∼
60
°
C
3.9 A
3.0 A
2.6 A
40
°
C or less
5.5 A
5.0 A
4.5 A
40
∼
50
°
C
5.5 A
5.0 A
4.5 A
4022 PL-W
50
∼
60
°
C
5.2 A
4.0 A
3.6 A
40
°
C or less
9.5 A
8.6 A
7.5 A
40
∼
50
°
C
9.5 A
8.6 A
7.5 A
4037 PL-W
50
∼
60
°
C
9.0 A
6.9 A
6.0 A
40
°
C or less
14.3 A
13.0 A
13.0 A
40
∼
50
°
C
14.3 A
13.0 A
13.0 A
4055 PL-W
50
∼
60
°
C
13.6 A
10.4 A
10.4 A
40
°
C or less
17.0 A
17.0 A
14.8 A
40
∼
50
°
C
17.0 A
17.0 A
14.8 A
4075
PL-W
50
∼
60
°
C
16.2 A
13.6 A
11.8 A
40
°
C or less
27.7 A
25.0 A
25.0 A
40
∼
50
°
C
27.7 A
25.0 A
25.0 A
4110 PL-W
50
∼
60
°
C
26.3 A
20.0 A
20.0 A
40
°
C or less
33.0 A
30.0 A
26.0 A
40
∼
50
°
C
33.0 A
30.0 A
26.0 A
4150
PL-W
50
∼
60
°
C
31.4 A
24.0 A
20.8 A
Summary of Contents for Q9 Plus ASD
Page 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Page 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Page 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Page 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Page 429: ......
Page 430: ......