E6581611
E-8
5
5.6
Setting the electronic thermal
: Overload characteristic selection
: Motor electronic-thermal protection level 1
: Electronic-thermal protection characteristic selection
3
: Motor electronic-thermal protection level 2
: Motor 150% overload detection time
: Inverter overload detection method
: Electronic-thermal memory
: Overload alarm level
Function
This parameter allows selection of the appropriate electronic thermal protection characteristics according to
the particular rating and characteristics of the motor.
[Parameter setting]
Title
Function
Adjustment range
Default setting
Overload characteristic
selection
0: - *4
1: Constant torque characteristic
(
150%-60s
)
2: Variable torque characteristic
(
120%-60s
)
0
Motor electronic-thermal
protection level 1
10 – 100 (%) / (A) *1
100
Setting
value
Overload
protection
Overload
stall
0 valid
invalid
1 valid
valid
2 invalid
invalid
3
Standard
motor
invalid valid
4 valid
invalid
5 valid
valid
6 invalid
invalid
Electronic-thermal
protection characteristic
selection
7
VF motor
(special
motor)
invalid valid
0
f173
Motor electronic-thermal
protection level 2
10 – 100 (%) / (A) *1
100
f607
Motor 150% overload
detection time
10 – 2400 (s)
300
Inverter overload detection
method
0: 150%-60s (120%-60s)
1: Temperature estimation
0
Summary of Contents for Q9 Plus ASD
Page 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Page 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Page 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Page 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Page 429: ......
Page 430: ......