E6581611
F-34
6
■
Setting of switching terminals
To switch to motor 2, assign the following functions to a terminal not being used. It is also possible to switch
to acceleration/deceleration 2 (AD2). Refer to section 6.15.1 for details.
It is possible to set 3 functions for terminal F and R, and 2 functions for terminal S1 and RES.
Input terminal function number
24
AD2
26
AD3
28
VF2
32
OCS2
152
MOT2
Parameters changed from applicable parameters and
default standards
OFF OFF
OFF
OFF
OFF
Default setting :
pt
,
vl
,
vlv
,
vb
,
thr
,
acc
,
dec
,
fs02
,
f601
ON OFF
OFF
OFF
OFF
acc
¤
fs00
、
dec
¤
f501
、
f502
¤
fs03
OFF ON
OFF
OFF
OFF
acc
¤
fs10
、
dec
¤
f511
、
f502
¤
fs12
During stop :
pt
¤
V/F constant ,
vl
¤
f170
,
vlv
¤
f171
,
vb
¤
f172
,
thr
¤
f173
OFF OFF ON
OFF
OFF
During run :
vl
¤
f170
,
vlv
¤
f171
,
vb
¤
f172
OFF OFF
OFF
ON OFF
f601
¤
f185
- OFF - - ON
→
,
→
,
→
,
→
,
→
(
is fixed when
=
or
),
→
,
→
,
→
,
→
Note 1: Each of the following numbers (25, 27, 29, 33, 153) are reverse signals.
Note 2:
pt
and "V/F constant" cannot be switched while running. Stop the motor before switching.
vl
and
f170
,
vlv
and
f171
,
vb
and
f172
can be switched while running.
Note 3: If motor is switched, the setting to retain and subtract an integral value of motor electronic thermal is possible.
Refer to section 5.6 for details.
■
Example of setting a terminal for switching: Sink logic
F (F: Forward run)
CC
S2(VF2)
S3(OCS2)
S1(AD2)
Forward run command
2nd acceleration/deceleration switch
2nd stall prevention operation switch
2nd V/F setting switch