E6581611
E-2
5
Adjustment scale with parameter
(Meter adjustment)
Connect meters as shown below.
[Example of how to adjust the FM terminal frequency meter]
* Use the meter's adjustment screw to pre-adjust zero-point.
* Adjust
f691
and
f692
in advance in case of 4-20mA output.
Operation panel action
LED display
Operation
-
.
Displays the output frequency.
(When standard monitor display selection
is set to
)
The first basic parameter “
” (history function) is displayed.
Turn the setting dial to select
.
.
Output frequency can be displayed by pressing the center of the
setting dial.
.
Turn the setting dial to adjust the meter.
The meter’s indicator will change by turning setting dial.
(The inverter displays output frequency and it will not change with the
setting dial)
⇔
Press the center of the setting dial to save the meter's adjustments.
and the frequency are displayed alternately.
+
.
The display returns to displaying output frequency.
(When standard monitor display selection
is set to
[output frequency])
FM
CC
=
Inverter
FM
CC
Inverter
The reading of the
meter will fluctuate
during scale
adjustment.
=
The reading of the
meter will
fluctuate during
scale adjustment.
+
-
+
-
* Optional QS-60T frequency
meter is available.
* Meter with a maximum
scale of 1.5x the inverter's
rated output current is
recommended.
<Displaying output frequency>
<Displaying output current>
MODE
MODE
MODE
Summary of Contents for Q9 Plus ASD
Page 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Page 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Page 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Page 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Page 429: ......
Page 430: ......