E6581611
K-36
11
Table of output terminal functions 3
Function
No.
Code Function
Action
Reference
92
DATA1
Designated data output 1
ON: bit0 of FA50 is ON
OFF: bit0 of FA50 is OFF
6.38
93
DATA1N
Inversion of designated data output 1
Inversion of DATA1
94
DATA2
Designated data output 2
ON: bit1 of FA50 is ON
OFF: bit1 of FA50 is OFF
95
DATA2N
Inversion of designated data output 2
Inversion of DATA2
106 LLD
Light
load
output
ON: Less than heavy load torque (
f335
~
f338
)
OFF: heavy load torque (
f335
~
f338
) or more
6.21
107
LLDN
Inversion of light load output
Inversion of LLD
108 HLD Heavy
load
output
ON: Heavy load torque (
f335
~
f338
) or more
OFF: Less than heavy load torque (
f335
~
f338
)
109 HLDN Inversion of
heavy load output
Inversion of HLD
120
LLS
Lower limit frequency stop
ON: Lower limit frequency continuous operation
OFF: Other than those above
6.13
121
LLSN
Inversion of lower limit frequency stop
Inversion of LLS
122
KEB
Power failure synchronized operation
ON: Power failure synchronized operation
OFF: Other than those above
6.19.2
123 KEBN Inversion
of power failure synchronized
operation
Inversion of KEB
124
TVS
Traverse in progress
ON: Traverse in progress
OFF: Other than those above
6.40
125
TVSN
Inversion of traverse in progress
Inversion of TVS
126
TVSD
Traverse deceleration in progress
ON: Traverse deceleration in progress
OFF: Other than those above
127
TVSDN
Inversion of traverse deceleration in
progress
Inversion of TVSD
128
LTA
Parts replacement alarm
ON: Any one of cooling fan, control board capacitor, or main
circuit capacitor reaches parts replacement time
OFF: Any one of cooling fan, control board capacitor, or main
circuit capacitor does not reach parts replacement time
6.29.15
129
LTAN
Inversion of parts replacement alarm
Inversion of LTA
130
POT
Over-torque detection pre-alarm
ON: Torque current is 70% of
f616
setting value or more
OFF: Torque current is less than
f616
x70%-
f619
6.29.10
131
POTN
Inversion of over-torque detection pre-alarm
Inversion of POT
132
FMOD
Frequency setting mode selection 1/2
ON: Select frequency setting mode selection 2 (
f207
)
OFF: Select frequency setting mode selection 1 (
fmod
)
5.8
133
FMODN
Inversion of frequency setting mode
selection 1/2
Inversion of FMOD
136
FLC
Panel / remote selection
ON: Operation command or panel
OFF: Other than those above
6.2.1
137
FLCN
Inversion of panel / remote selection
Inversion of FLC
138
FORCE
Forced continuous operation in progress
ON: Forced continuous operation in progress
OFF: Other than those above
6.30
139
FORCEN
Inversion of forced continuous operation in
progress
Inversion of FORCE
140
FIRE
Specified frequency operation in progress
ON: Specified Frequency operation in progress
OFF: Other than those above
141
FIREN
Inversion of specified frequency operation in
progress
Inversion of FIRE