E6581611
F-50
6
•
The jog run setting terminal (RES-CC) is enabled when the value of operation frequency is that of the jog
run frequency and below.
This connection does not function when operation frequency exceeds the jog run frequency.
•
The motor can be operated in jog mode while the jog run setting terminals are connected (RES-CC).
•
Jog run has priority to new operation command given during operation.
•
Even for
f261
=
0
or
1
, an emergency DC braking (
f603
=
2
) is prior to the setting.
•
No limits are imposed to the jog run frequency by the upper-limit frequency (parameter
ul
).
■
Panel jog mode (if
f262
is set to
1
)
•
The direction of rotation can change by using extension panel.
Using RKP007Z : Display switches to
fjog
and
rjog
by every pressing the FWD/REV key.
Using RKP002Z : Pressing the UP key changes display to
fjog
and pressing the DOWN key
changes display to
rjog
.
•
When
fjog
is displayed, the inverter will be placed in forward jog run mode as long as the
key is pressed.
•
When
rjog
is displayed, the inverter will be placed in reverse jog run mode as long as the
key is pressed.
•
If you press and hold down the key for 20 seconds or more, the key failure alarm “
e-17
” will
be displayed.
Here is the sequence in which modes change each time you press the key.
Standard monitor
mode
Status monitor
mode
Setting monitor
mode
Panel jog mode
M ODE
MODE
MODE
M ODE
Note: When the inverter is in operation (RUN lamp is blinking) or when an operation command is issued
(RUN lamp is lighting), the inverter cannot be switched to panel jog mode.
RUN
RUN
MODE
ST-CC
F-CC
R-CC
RES-
Frequency command input
Reverse
Forward
Forward
0
Set frequency
(
=
18
)
Forward
Summary of Contents for Q9 Plus ASD