E6581611
E-5
5
5.3 Maximum
frequency
: Maximum frequency
Function
1) Programs the range of frequencies output by the inverter (maximum output values).
2) This frequency is used as the reference for acceleration/deceleration time.
Output frequency
(Hz)
When
=80Hz
When
=60Hz
80Hz
60Hz
0 100% Frequency setting signal (%)
・
This function determines the value
in line with the ratings of the motor
and load.
・
Maximum frequency cannot be
adjusted during operation.To
adjust, first stop
the inverter.
+
If
is increased, adjust the upper limit frequency
as necessary.
[Parameter setting]
Title
Function
Adjustment range
Default setting
Maximum frequency
30.0-500.0 (Hz)
80.0