E6581611
G-5
7
List of logic input terminal function settings
Parameter
programmed value
Parameter
programmed value
Positive
logic
Negative
logic
Function
Positive
logic
Negative
logic
Function
No function
Integrating wattmeter
(kWh) display
clear
Forward run command
Trace back trigger signal
Reverse run command
Light-load high-speed operation
prohibitive signal
Standby
Holding of RY-RC terminal output
Reset command
Holding of OUT-NO terminal output
Preset-speed command 1
Frequency UP *2
Preset-speed command 2
Frequency DOWN *2
Preset-speed command 3
Clear frequency UP/DOWN *2
Preset-speed command 4
Coast stop command
Jog run mode
Forward/reverse selection
Emergency stop by external signal
Run/Stop command
DC braking command
Frequency reference command forced
switching
2nd acceleration/deceleration
Frequency setting mode terminal block
3rd acceleration/deceleration
Command mode terminal block
2nd V/F control mode switching
Parameter editing permission
2nd stall prevention level
Fast stop command 1
PID control prohibition
Fast stop command 2
External thermal error input
Traverse permission signal
Forced local from communication
Low voltage operation
Operation hold (hold of 3-wire operation)
Forward
deceleration
PID integral/differential clear
Forward
stop
PID characteristics switching
Reverse
deceleration
Forced run operation
Reverse
stop
Fire speed operation
to
Factory specific coefficient *1
Acceleration/deceleration suspend signal
No.2 motor switching
Power failure synchronized signal
Parameter editing prohibition
Factory specific coefficient *1
Parameter reading prohibition
Factory specific coefficient *1
*1: Factory specific coefficients are manufacturer setting menus. Do not change the value of these parameters.
*2: Active when
(frequency setting mode selection) =
(UP/DOWN from external logic input) is set.
The frequency setup range is from
to
(maximum frequency). The acceleration/deceleration time
relative to the set frequency is
/
while the acceleration/deceleration speed is not switched.
☆
Refer to section
11.6 for details about the input terminal function.