E6581611
C-7
3
3.2.2
How to set the frequency
[Example of
fmod
setting procedure]
fmod
=
1
: Setting the frequency by the terminal VIA
Panel operation
LED display
Operation
0
0
Displays the output frequency (operation stopped).
(When standard monitor display selection
f710
=
0
[output frequency])
auh
Displays the first basic parameter [History (
auh
)].
fmod
Turn the setting dial, and select "
fmod
".
0
Press the center of the setting dial to read the parameter value.
(Standard default:
0
).
1
Turn the setting dial to change the parameter value to
(terminal block
VIA).
1
fmod
The parameter value is written.
fmod
and the parameter value are
displayed alternately several times.
* Pressing the MODE key twice returns the display to standard monitor mode (displaying output frequency).
(1) Setting using the keypad (
fmod
=
0
or
3
)
: Moves the frequency up
: Moves the frequency down
Example of operating from the panel (
=
: press in center to save)
Panel operation
LED display
Operation
Displays the output frequency.
(When standard monitor display selection
=
[output frequency])
Set the output frequency. (The frequency will not be saved if the
power is turned off in this state.)
Save the output frequency.
and the frequency are displayed
alternately.
Example of operating from the panel (
=
: save even if power is off)
Panel operation
LED display
Operation
Display the output frequency.
(When standard monitor display selection is set as
=
[output frequency])
Set the output frequency.
-
The frequency will be saved when the power is turned off in this
state.
MODE