E6581611
K-35
11
Table of output terminal functions 2
Function
No.
Code Function
Action
Reference
30
POLR
Braking resistor overload pre-alarm
ON: 50% or more of calculated value of
set
overload protection level
OFF: Less than 50% of calculated value of
set
overload protection level
6.19.4
31
POLRN
Inversion of braking resistor overload pre-
alarm
Inversion of POLR
40
RUN
Run/stop
ON: While operation frequency is output or DC braking is in
operation (
)
OFF: Operation stopped
7.2.2
41
RUNN
Inversion of run/stop
Inversion of RUN
42
HFL
Serious failure
ON: At trip *2
OFF: Other than those trip above
43
HFLN
Inversion of serious failure
Inversion of HFL
44 LFL Light
failure
ON: At trip (
~
,
~
,
,
~
,
)
OFF: Other than those trip above
45
LFLN
Inversion of light failure
Inversion of LFL
50
FAN
Cooling fan ON/OFF
ON: Cooling fan is in operation
OFF: Cooling fan is off operation
6.29.11
51
FANN
Inversion of cooling fan ON/OFF
Inversion of FAN
52
JOG
In jogging operation
ON: In jogging operation
OFF: Other than jogging operation
6.14
53
JOGN
Inversion of in jogging operation
Inversion of JOG
54
JBM
Operation panel / terminal block operation
ON: At terminal block operation command
OFF: Other than those operation above
6.2.1
55
JBMN
Inversion of operation panel/terminal block
operation
Inversion of JBM
56
COT
Cumulative operation time alarm
ON: Cumulative operation time is
or more
OFF: The cumulative operation time is less than
6.29.12
57
COTN
Inversion of cumulative operation time alarm
Inversion of COT
58
COMOP
Communication option communication error
ON: Communication error of communication option occurs
OFF: Other than those above
6.38
59
COMOPN Inversion of communication option
communication error
Inversion of COMOP
60
FR
Forward/reverse run
ON: Reverse run
OFF: Forward run
(Operation command state is output while motor operation is
stopped. No command is to OFF.)
7.2.2
61
FRN
Inversion of forward/reverse run
Inversion of FR
62
RDY1
Ready for operation 1
ON: Ready for operation (with ST / RUN)
OFF: Other than those above
63
RDY1N
Inversion of ready for operation 1
Inversion of RDY1
64
RDY2
Ready for operation 2
ON: Ready for operation (without ST / RUN)
OFF: Other than those above
65
RDY2N
Inversion of ready for operation 2
Inversion of RDY2
68
BR
Brake release
ON: Brake exciting signal
OFF: Brake releasing signal
6.22
69
BRN
Inversion of brake release
Inversion of BR
70
PAL
Pre-alarm
ON: One of the following is turned on
ON POL, POHR, POT, MOFF, UC, OT, LL stop, COT,
and momentary power failure deceleration stop.
Or
,
,
,
issues an alarm
OFF: Other than those above
7.2.2
71
PALN
Inversion of pre-alarm
Inversion of PAL
78
COME
RS485 communication error
ON: Communication error occurred
OFF: Communication works
6.38
79
COMEN
Inversion of RS485 communication error
Inversion of COME
*2: At trip
,
,
,
,
,
,
,
,
,
,
~
,
~
,
,
,
,
~
,
,
,
,
,
~
,
,
,
,
,
.
Summary of Contents for Q9 Plus ASD
Page 5: ...TM Q9 Plus Bypass ASD Bypass Box INSTALLATION OPERATION MANUAL June 2013 DN 68251 000 ...
Page 61: ...Q9 PLUS ASD LOW VOLTAGE DRIVE ...
Page 65: ...S15 ASD LOW VOLTAGE DRIVE ...
Page 80: ...E6581611 iv 15 Warranty O 1 16 Disposal of the inverter P 1 ...
Page 429: ......
Page 430: ......