![R&S SMJ100A Operating Manual Download Page 698](http://html1.mh-extra.com/html/rands/smj100a/smj100a_operating-manual_3086611698.webp)
Remote Control Commands
R&S
®
SMJ100A
682
Operating Manual 1403.7458.32 ─ 14
Parameters:
<Stop>
integer
Range:
0 to 8191
*RST:
0
Example:
BB:MCCW:EDIT:CARR:STOP 40
the carrier range stops at carrier 40.
Manual operation:
See
Trigger Settings
[:SOURce<hw>]:BB:MCCW:TRIGger:ARM:EXECute
.........................................................682
[:SOURce<hw>]:BB:MCCW:TRIGger:EXECute
.................................................................682
[:SOURce<hw>]:BB:MCCW:TRIGger:EXTernal:SYNChronize:OUTPut
............................... 683
[:SOURce<hw>]:BB:MCCW:TRIGger:OBASeband:DELay
................................................. 683
[:SOURce<hw>]:BB:MCCW:TRIGger:OBASeband:INHibit
................................................. 684
[:SOURce<hw>]:BB:MCCW:TRIGger:RMODe?
.................................................................684
[:SOURce<hw>]:BB:MCCW:TRIGger:SLENgth
................................................................. 685
[:SOURce<hw>]:BB:MCCW:TRIGger:SOURce
................................................................. 685
[:SOURce<hw>]:BB:MCCW:TRIGger[:EXTernal<ch>]:DELay
............................................. 685
[:SOURce<hw>]:BB:MCCW:TRIGger[:EXTernal<ch>]:INHibit
............................................. 686
[:SOURce<hw>]:BB:MCCW[:TRIGger]:SEQuence
.............................................................686
[:SOURce<hw>]:BB:MCCW:TRIGger:ARM:EXECute
Stops signal generation for trigger modes Armed_Auto and Armed_Retrigger. A subse-
quent internal or external trigger event restart signal generation.
Example:
BB:MCCW:TRIG:SOUR INT
sets internal triggering.
BB:MCCW:TRIG:SEQ ARET
sets Armed_Retrigger mode, i.e. every trigger event causes sig-
nal generation to restart.
BB:MCCW:TRIG:EXEC
executes a trigger, signal generation is started.
BB:MCCW:TRIG:ARM:EXEC
signal generation is stopped.
BB:MCCW:TRIG:EXEC
executes a trigger, signal generation is started again.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:TRIGger:EXECute
Executes a trigger. The internal trigger source must be selected using the command
MCCW:TRIGger:SOURce INTernal
and a trigger mode other than
AUTO
must be
selected using the command
:BB:MCCW:TRIGger:MODE
.
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...