Remote Control Basics
R&S
®
SMJ100A
455
Operating Manual 1403.7458.32 ─ 14
7. To enable the LOCAL key, use the command
>R
.
8. To return to manual operation, see
Chapter 6.2.2, "Returning to Manual Opera-
Tip:
Switching from manual operation to remote control and vice versa does not
affect the other instrument settings.
6.2.3.3
Remote Control over LAN using Socket Communication
This chapter provides an example on how to establish a remote control connection
over telnet protocol and a simple sockets-based program example that can be further
developed.
Setting up a Telnet Connection
To control the software, only a telnet program is required. The telnet program is part of
every operating system.
1. To establish a Telnet connection with the R&S
SMJ, start the telnet program.
2. Enter the access string to connect to the instrument and confirm with ENTER.
The access string is composed of the open command short form) and the socket
address. The socket address is a combination of the IP address or the host name
of the R&S
SMJ and the number of the port configured for remote-control via tel-
net. The R&S
SMJ uses the port number 5025 for remote connection via Telnet.
Example:
o 10.113.1.150 5025
The connection to the instrument is set up and you can send remote-control com-
mands.
3. Even if the cursor is not visible on the screen, enter blind a remote-control com-
mand and confirm with "Enter".
Starting a Remote Control Session
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...