Remote Control Commands
R&S
®
SMJ100A
726
Operating Manual 1403.7458.32 ─ 14
[:SOURce<hw>]:IQ:IMPairment:QUADrature[:ANGLe]
<Angle>
Sets the quadrature offset for the I/Q modulation.
Parameters:
<Angle>
float
Range:
-10 to 10
Increment: 0.01
*RST:
0
Default unit: DEG
Example:
IQ:IMP:QUAD:ANGL -5DEG
sets the quadrature offset to -5 degrees.
Manual operation:
See
[:SOURce<hw>]:IQ:IMPairment[:STATe]
<State>
Activates/deactivates the three impairment or correction values LEAKage, QUADrature
and IQRatio for the analog signal in the I/Q modulator.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
IQ:IMP OFF
deactivates I/Q impairment.
Manual operation:
See
[:SOURce<hw>]:IQ:SOURce
<Source>
Selects the input signal for the I/Q modulator.
Selecting
ANALog
(Wideband I/Q In) switches off:
●
SOURce:AM:STATe OFF
●
SOURce:BBAM:STATe OFF
●
SOURce:BB:DM:STATe OFF
●
SOURce:BB:<Dig. Standard>:STATe OFF
Parameters:
<Source>
BASeband | ANALog | DIFFerential
Example:
IQ:SOUR ANAL
selects an external analog signal as the input signal. The signal
must be applied at the inputs I and Q.
Manual operation:
See
[:SOURce<hw>]:IQ:STATe
<State>
Activates I/Q modulation.
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...