Remote Control Commands
R&S
®
SMJ100A
518
Operating Manual 1403.7458.32 ─ 14
Manual operation:
See
:BERT:SETup:TYPE
<Type>
Selects the PRBS sequence. The data generated by the PRBS generator is used as a
reference for the measurement.
Parameters:
<Type>
PRBS9 | PRBS11 | PRBS15 | PRBS16 | PRBS20 | PRBS21 |
PRBS23
*RST:
PRBS9
Example:
BERT:SET:TYPE PN15
sets a pseudo random binary sequence consisting of 32767 bits.
Manual operation:
See
:BLER:SETup:TYPE
<Type>
Queries the CRC polynomial used. CCITT CRC 16 : G(x) = x
16
+ x
12
+ x
5
+ x
1
is the
CRC polynomial supported.
Parameters:
<Type>
CRC16
*RST:
CRC16
Example:
BLER:SET:TYPE
queries the type of measurement.
Example:
Response: CRC16
Manual operation:
See
:BLER:SETup:TIMeout
<Timeout>
:BERT:SETup:TIMeout
<Timeout>
Sets the time out.
Parameters:
<Timeout>
float
Range:
0.1 to 1
Increment: 0.001
*RST:
0.1
:BLER:STARt
:BERT:STARt
Starts a continuous measurement.
These commands automatically set
BERT:SEQuence
or
BLER:SEQuence
to AUTO
and
BERT:STATe
or
BLER:STATe
to ON.
BERT and BLER Subsystems
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...