Remote Control Commands
R&S
®
SMJ100A
692
Operating Manual 1403.7458.32 ─ 14
Parameters:
<Multiplier>
integer
Range:
1 to 64
*RST:
4
Example:
BB:MCCW:CLOC:SOUR EXT
selects the external clock source. The clock is supplied via the
CLOCK connector.
BB:MCCW:CLOC:MODE MSAM
selects clock type "Multiple Samples", i.e. the supplied clock has
a rate which is a multiple of the sample rate.
BB:MCCW:CLOC:MULT 12
the multiplier for the external clock rate is 12.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:CLOCk:SOURce
<Source>
Selects the source for the digital modulation clock.
Parameters:
<Source>
INTernal | EXTernal | AINTernal
INTernal
The internal clock reference is used.
EXTernal
The external clock reference is supplied to the CLOCK connec-
tor.
*RST:
INTernal
Example:
BB:MCCW:CLOC:SOUR EXT
selects an external clock reference. The clock is supplied via the
CLOCK connector.
Manual operation:
See
7.16.3.7
SOURce:BB:MEASurement Subsystem
This subsystem contains the commands for measuring the level values of the digital
baseband signal.
Monitoring the measurement of the digital I/Q baseband signal requires the baseboard
version “DacBoard 1141.8190.02” or higher. Up to baseboard version DacBoard
1141.8090.xx only the calculated signal levels are provided.
The currently equipped DacBoard is listed in the dialog "Setup > System > Hardware
Config, section Baseband Assembly" (see
Chapter 5.2.3.2, "Hardware Config"
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...