Instrument Function
R&S
®
SMJ100A
186
Operating Manual 1403.7458.32 ─ 14
If the data is not cyclically continued, the measurement can be selectively interrupted
and restarted. Certain data sections and frames that have been marked as faulty can
be excluded from the measurement.
5.4.10.1
General Settings
State
Switches the bit error rate measurement on/off. Depending on the selection in the
"Mode" box, either a continuous measurement ("Auto") or a single measurement ("Sin-
gle") is carried out. A single measurement must be started by clicking the "Execute
Single" button.
Remote command:
Bit Error Rate
Displays the measured bit error rate.
The bit error rate is the ratio of occurred errors to transmitted data bits.
The display unit can be selected in the box to the right of the value.
"ENG"
The bit error rate is output in exponential notation with the exponent –
3 or –6.
"SCI"
The bit error rate is output in scientific notation, i.e. standardized to
one place to the left of the decimal.
"%"
The bit error rate is output in percent.
"ppm"
The bit error rate is output in parts per million.
Remote command:
Bit and Block Error Rate Measurements - BERT Block
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...