Remote Control Commands
R&S
®
SMJ100A
636
Operating Manual 1403.7458.32 ─ 14
Example:
BB:DM:TRIG:SOUR INT
sets internal triggering.
BB:DM:TRIG:SEQ RETR
sets Retrigger mode, i.e. every trigger event causes signal gen-
eration to restart.
BB:DM:TRIG:EXEC
executes a trigger.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger:EXTernal:SYNChronize:OUTPut
<Output>
(enabled for "Trigger Source" External)
Enables/disables output of the signal synchronous to the external trigger event.
Parameters:
<Output>
0 | 1 | OFF | ON
ON
The signal calculation starts simultaneously with the external
trigger event but because of the instrument’s processing time
the first samples are cut off and no signal is outputted. After
elapsing of the internal processing time, the output signal is syn-
chronous to the trigger event.
OFF
The signal output begins after elapsing of the processing time
and starts with sample 0, i.e. the complete signal is outputted.
This mode is recommended for triggering of short signal sequen-
ces with signal duration comparable with the processing time of
the instrument.
*RST:
1
Example:
BB:DM:TRIG:SOUR EXT
sets external triggering.
BB:DM:TRIG:EXT:SYNC:OUTP ON
enables synchrounous output to external trigger
Manual operation:
See
"Sync. Output to External Trigger"
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut:DELay:FIXed
<Fixed>
The command restricts the marker delay setting range to the dynamic range. In this
range the delay can be set without restarting the marker and signal. If a delay is
entered in setting ON but is outside this range, the maximum possible delay is set and
an error message is generated.
The numeric suffix in
OUTPut
has no significance for this command, since the setting
always affects every marker.
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...