![R&S SMJ100A Operating Manual Download Page 686](http://html1.mh-extra.com/html/rands/smj100a/smj100a_operating-manual_3086611686.webp)
Remote Control Commands
R&S
®
SMJ100A
670
Operating Manual 1403.7458.32 ─ 14
Example:
BB:IMP:IQR 3 PCT
sets the imbalance to 3 percent.
BB:IMP:IQR?
queries the imbalance.
Response: 0.259000
the value is returned in dB
Manual operation:
See
"Gain Imbalance - Digital Impairments"
[:SOURce<hw>]:BB:IMPairment:LEAKage:I
<I>
This command sets the carrier leakage amplitude for the I-signal component.
Parameters:
<I>
float
Range:
-10 to 10
Increment: 0.01
*RST:
0
Default unit: PCT
Example:
BB:IMP:LEAK:I 3 PCT
sets the leakage for the I-component to 3 percent.
Manual operation:
See
"I/Q Offset - Digital Impairments"
[:SOURce<hw>]:BB:IMPairment:LEAKage:Q
<Q>
This command sets the carrier leakage amplitude for the Q-signal component.
Parameters:
<Q>
float
Range:
-10 to 10
Increment: 0.01
*RST:
0
Default unit: PCT
Example:
BB:IMP:LEAK:Q 3 PCT
sets the leakage for the Q-component to 3 percent.
Manual operation:
See
"I/Q Offset - Digital Impairments"
[:SOURce<hw>]:BB:IMPairment:QUADrature[:ANGLe]
<Angle>
This command sets the quadrature offset for the digital I/Q signal.
Parameters:
<Angle>
float
Range:
-10 to 10
Increment: 0.01
*RST:
0
Default unit: DEG
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...