Remote Control Commands
R&S
®
SMJ100A
587
Operating Manual 1403.7458.32 ─ 14
Example:
BB:ARB:TRIG:SOUR EXT
sets external triggering
BB:ARB:TRIG:MODE ARET
selects the Armed_Retrigger mode.
BB:ARB:TRIG:RMOD?
queries the current status of waveform output.
Response: RUN
the waveform is output, an external trigger was executed.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLENgth
<SLength>
The command defines the length of the signal sequence to be output in the Single trig-
ger mode. The unit is defined with command
SOUR:BB:ARB:TRIG:SLUNit
. It is pos-
sible to output deliberately just part of the waveform, an exact sequence of the wave-
form, or a defined number of repetitions of the waveform.
Parameters:
<SLength>
integer
Range:
1 to dynamic
*RST:
1
Default unit: sample
Example:
BB:ARB:SEQ SING
sets trigger mode Single.
BB:ARB:TRIG:SLUN SAMP
sets unit Samples for the entry of sequence length.
BB:ARB:TRIG:SLEN 200
sets a sequence length of 200 samples. The first 200 samples of
the current waveform will be output after the next trigger event.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLUNit
<SLUnit>
The command defines the unit for the entry of the length of the signal sequence
(
SOUR:BB:ARB:TRIG:SLEN
) to be output in the "Single" trigger mode
(
SOUR:BB:ARB:SEQ SING
).
Parameters:
<SLUnit>
SEQuence | SAMPle
*RST:
SEQuence
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...