Remote Control Commands
R&S
®
SMJ100A
653
Operating Manual 1403.7458.32 ─ 14
Example:
BB:DM:PRAM:SHAP COS
selects a cosine-shaped rise and fall for the transmitted power
edge.
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp:SOURce
<Source>
Sets the source for the power ramp control signals.
Parameters:
<Source>
INTernal | EXTernal
INTernal
The internal control signals LEV_ATT and BURST are used.
Control signals are stored in dedicated lists. When remote con-
trol is in use, the list to be used is defined, selected and enabled
with the aid of
SOURce:BB:DM:CLISt:...
commands.
EXTernal
The digital control signals LEV_ATT and BURST are supplied
via the control signal inputs on the AUX I/O connector.
*RST:
INTernal
Example:
BB:DM:PRAM:SOUR INT
enables the use of internal control signals for power ramp con-
trol.
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp:TIME
<Time>
Sets the power ramping rise time and fall time for a burst.
Parameters:
<Time>
float
Range:
0.25 to 16
Increment: 0.01
*RST:
1
Default unit: symbol
Example:
BB:DM:PRAM:TIME 2
sets a time of 2 symbols for the edges to rise and fall.
Manual operation:
See
[:SOURce<hw>]:BB:DM:PRAMp[:STATe]
<State>
The command enables or disables power ramping.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...