Instrument Function
R&S
®
SMJ100A
311
Operating Manual 1403.7458.32 ─ 14
Crest Factor - Digital Impairments
Indicates the crest factor of the baseband signal.
The crest factor is calculated from the two level parameters as follows:
Crest[dB]=Peak_Power[dBFs]/Signal_Power[dBFs]
Remote command:
Peak Power - Digital Impairments
Indicates the peak power of the baseband signal relative to full scale of 0.5 V (in terms
of dB full scale).
Remote command:
Power - Digital Impairments
Indicates the power of the baseband signal relative to full scale of 0.5 V (in terms of dB
full scale).
Remote command:
5.7.4.2
Baseband Signal Power Measurement
This section applies to instruments equipped with a baseboard version
DacBoard
1141.8090.xx
or higher.
The power measurement of the I/Q baseband signal is monitored and displayed in the
dialog. The measurement can be performed either with or without interfering.
State - Digital Impairments - Measurement
Activates the measurement of the digital I/Q baseband signal.
Impairment of Digital I/Q Signal and Noise Generator - AWGN/IMP Block