Remote Control Commands
R&S
®
SMJ100A
558
Operating Manual 1403.7458.32 ─ 14
The general purpose input (
GPINput
) is available for USER interfaces 1 and 2 only.
Parameters:
<Source>
AMARk4 | BMARk4 | ACW | BCW | ABLank | BBLank | AHOP |
BHOP | BBITclock | BSYMbolclock | BATTenuator | BBURst |
ATRig | BTRig | GPINput
*RST:
USER1 = AMARker4; USER 2 = ACW; USER 3 =
ABLank; USER 4 = ATRig
Example:
OUTP:USER2 AMAR
causes the marker signal to be output at the USER2 pin of the
AUX I/O interface.
OUTP:CLOC:MODE SYMB
specifies that the internally generated clock pulse is a symbol
clock pulse.
OUTP:CLOC:STAT ON
activates output of the symbol clock pulse at the USER2 pin
Manual operation:
See
7.15 SENSe, READ and INITiate Subsystems
The SENSe subsystem contains the commands for configuring the power measure-
ments with R&S NRP-Zxx power sensor(s) connected to the generator. The measure-
ment is started and the measurement result retrieved with the
READ
command. The
description of this commands is included in the following.
Up to four sensors can be connected to the signal generator. They are distinguished by
means of the suffix under SENSe:
●
Power sensor connected to the SENSOR port =
SENSe[1]
●
power sensor connected first to one of the USB interfaces =
SENSe 2
●
further power sensors connected second and third via USB =
SENSe 3
and
SENSe
4
:SENSe<ch>[:POWer]:APERture:DEFault:STATe
............................................................. 559
:SENSe<ch>[:POWer]:APERture:TIMe
.............................................................................559
:INITiate<ch>[:POWer]:CONTinuous
................................................................................559
:SENSe<ch>[:POWer]:CORRection:SPDevice:STATe
....................................................... 560
:SENSe<ch>[:POWer]:DISPlay:PERManent:STATe
.......................................................... 561
:SENSe<ch>[:POWer]:DISPlay:PERManent:PRIority
.........................................................561
:SENSe<ch>[:POWer]:FILTer:LENGth:AUTO?
..................................................................561
:SENSe<ch>[:POWer]:FILTer:LENGth[:USER]
..................................................................562
:SENSe<ch>[:POWer]:FILTer:NSRatio
.............................................................................562
:SENSe<ch>[:POWer]:FILTer:NSRatio:MTIMe
..................................................................563
:SENSe<ch>[:POWer]:FILTer:SONCe
..............................................................................563
:SENSe<ch>[:POWer]:FILTer:TYPE
................................................................................ 563
:SENSe<ch>[:POWer]:LOGGing:STATe
...........................................................................564
..................................................................................564
SENSe, READ and INITiate Subsystems
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...