background image

OWNER'S MANUAL 

 

TG2000i 

 

DIGITAL GENERATOR 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 

 

 

 

 

 

 

YONGKANG ZHONGJIAN TOOLS MANUFACTURE CO.,LTD. 

 

 

Summary of Contents for TG2000i

Page 1: ...OWNER S MANUAL TG2000i DIGITAL GENERATOR YONGKANG ZHONGJIAN TOOLS MANUFACTURE CO LTD...

Page 2: ...ner s manual before operating this generator Generators produce carbon monoxide a poisonous colorless odorless gas that can cause death or serious injury Indoor use of a generator can kill quickly Gen...

Page 3: ...ut the generator consult an authorized dealer Our generators are designed to give safe and dependable service if operated according to instructions Read and understand the Owner s Manual before operat...

Page 4: ...LOCATIONS 7 3 COMPONENT INDENTIFICACTION 8 4 PRE OPERATION CHECK 10 5 STARTING THE ENGINE 13 6 GENERATOR USE 16 7 STOPPING THE ENGINE 24 8 MAINTENANCE 26 9 TRANSPORTING STORAGE 31 10 TROUBLE SHOOTING...

Page 5: ...protections are to be observed The muffler becomes very hot during operation and remains hot for a while after stopping the engine Be careful not to touch the muffler while it is hot Let the engine co...

Page 6: ...oline with a pump octane rating of 86 RON 97 or higher Improper maintenance or failure to correct a problem can cause a malfunction in which you can be seriously hurt or killed If service tasks are mo...

Page 7: ...tial hazards that can cause serious injury Read the labels and safety notes and precautions described in this manual carefully If a label comes off or becomes hard to read contact your dealer for a re...

Page 8: ...3 COMPONENT IDENTIFICATION 8...

Page 9: ...r identifies your particular unit and is important when ordering parts and accessories Engine serial number 158FYYMMDD0001 The serial number can be found engraved on the crankcase beside the oil filte...

Page 10: ...r viscosities show in the chart may be used when the average temperature in your area is within the indicated ranger 1 Placed the generator on the level surface 2 Loosen the cover screw and remove the...

Page 11: ...d water in the fuel tank When the engine is stopped remove the fuel tank cap and check the fuel level Refill the fuel tank if the fuel level is low After refueling tighten the fuel tank cap securely G...

Page 12: ...es greater than the shown above are not covered under warranty fuel can damage the paint and plastic Be carefully not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not cov...

Page 13: ...starting the engine disconnect any loads from the AC and DC terminals 1 Turn the fuel cap vent lever fully clockwise to the I position 2 Turn the engine switch to the ON position 3 Move the choke lev...

Page 14: ...against the engine return it gently to prevent damage to the starter or housing 5 If the choke lever was moved to the START position to start the engine gradually move it to the RUN position as the e...

Page 15: ...r each 1000 305 m increase in altitude The effect of altitude on the horsepower will be greater than this if no carburetor modification is made When the carburetor has been modified for the high altit...

Page 16: ...connected must be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit This could cause the damage to the generator or to el...

Page 17: ...ed off and plug in the appliance Substantial overloading that continuously lights the overload indicator light red may damage the generator Marginal overloading that temporarily lights the overload in...

Page 18: ...erload indicator light red comes ON and investigate the overload source Before connecting an appliance to the generator check that it is in good order and that its electrical rating does not exceed th...

Page 19: ...set the engine switch to STOP stop the engine at once and then start the engine again 3 Confirm that the equipment to be used is switched off and insert the plug of the equipment to be used into the A...

Page 20: ...the engine must be stopped by setting the respective engine switch to STOP In case of normal operation In case of overload operation or short circuit When equipment requiring a large starting power li...

Page 21: ...black lead to the negative battery terminal To prevent the possibility of creating a spark near the battery connect charging cable first to the generator then to the battery Disconnect cable first at...

Page 22: ...ll trip the DC circuit protector PUSH button extendsout If this happens wait a few minute before pushing in the circuit protector to resume operation In order to acquire both the best effect and the m...

Page 23: ...ould be in the OFF position When high electrical loads are connected simultaneously turn the Intelligent Throttle switch to the OFF position to reduce voltage fluctuation or shutdown Appliances with l...

Page 24: ...ency turn the engine switch to the OFF position Under normal conditions use the following procedure 1 Switch off the connected equipment and pull the inserted plug 2 Turn the engine switch to the OFF...

Page 25: ...e engine cool well turn the cap vent lever fully counterclockwise to the O position Be sure the fuel cap vent lever choke and the engine switch are OFF when stopping transporting and or storing the ge...

Page 26: ...e generator Maintenance Schedule REGULAR SERVICE PERIOD 1 Perform at every indicated month or operating hour interval whichever occurs first ITEM EACH USE FIRST MONTH OR 10 HOURS EVERY 3 MONTHS OR 50...

Page 27: ...ver OFF before draining 1 Loosen the cover screw and remove the left side maintenance cover 2 Remove the oil filler cap 3 Drain dirty oil into a container thoroughly 4 Refill with the recommended oil...

Page 28: ...y are flammable and explosive under certain conditions 1 Loosen the cover screw and remove the left side maintenance cover 2 Loosen the air cleaner cover screw and remove the air cleaner cover 3 Wash...

Page 29: ...To ensure proper engine operation the spark plug must be properly gapped and free of deposits 1 Remove the spark plug maintenance cover 2 Remove the spark plug cap 3 Clean any dirt from around the sp...

Page 30: ...plug in by hand to prevent cross threading 8 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench to compress its washer If a used plug is being reinstalled it...

Page 31: ...in an upright position while transporting Exercising the Generator It is essential that the generator be exercised on a regular basis This will prevent the accumulation of varnish or sludge in the fu...

Page 32: ...blespoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil and then reinstall the spark plug 5 Reinstall the spark plug cap on the spark plug securely 6...

Page 33: ...to ground 4 Pull the recoil starter spark should jump across the gap 33 Is there fuel in the tank Refill the fuel tank Is the engine switch on Turn the engine switch on Is there enough oil in the eng...

Page 34: ...dealer Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Replace the electrical appliance or equipment Take the electrical appliance or equipment...

Page 35: ...e horizon shaft air cooled SOHC gasoline engine Displacement 105 7 cc Compression ratio 8 5 1 Engine speed 4500 5000rpm with Intelligent Throttle switch OFF Ignition system T C I Spark plug NHSP LD A7...

Page 36: ...12 WIRING DIAGRAM 36...

Page 37: ...ZHONG JIAN TOOLS MANUFACTURE CO LTD No 27 Yongdong East Road Great wall Industry Area Yongkang Zhejiang China Tel 0086 579 87233668 Fax 0086 579 87232599 E mail zjtools zjtools cn Http www zjtools cn...

Reviews: