![background image](http://html1.mh-extra.com/html/yongkang/tg2000i/tg2000i_owners-manual_3462484021.webp)
The DC receptacle should only be used for charging 12 volt automotive-type batteries, the zero load
voltage is 15V-30V. The DC charging output is not regulated.
■
In DC operation, turn the Intelligent Throttle switch to the OFF position.
1. Before connecting charging cables to a battery that is installed in a vehicle, disconnect the
vehicles grounded battery cable from the negative (-) battery terminal.
2.
Connect the charging cables to the DC receptacle of the generator.
3.
connect the red lead of battery charging cable to the positive (+) battery terminal and the black
lead to the negative (-) battery terminal .
■
To prevent the possibility of creating a spark near the
battery, connect charging cable first to the generator, then to the
battery. Disconnect cable first at the battery.
■
Reconnect the vehicle's grounded battery cable after the charging
cables are removed. This procedure will prevent the possibility of a
short circuit and sparks if you make accidental contact between a
battery terminal and the vehicle's frame or body.
■
Do not attempt to start an automobile engine with the generator still
connected to the battery. The generator may be damaged.
■
Connect the positive battery terminal to the positive charging cord.
Do not reverse the charging cables, or serious damage to the
generator and/or battery may occur.
21