![R&S SMJ100A Operating Manual Download Page 700](http://html1.mh-extra.com/html/rands/smj100a/smj100a_operating-manual_3086611700.webp)
Remote Control Commands
R&S
®
SMJ100A
684
Operating Manual 1403.7458.32 ─ 14
Example:
BB:MCCW:TRIG:SOUR EXT
selects an external trigger
BB:MCCW:TRIG:DEL 200
sets a delay of 200 samples for the trigger.
[:SOURce<hw>]:BB:MCCW:TRIGger:OBASeband:INHibit
<Inhibit>
Sets the number of samples by which a restart is to be inhibited following a trigger
event. This command applies only in the case of external triggering.
Parameters:
<Inhibit>
integer
Range:
0 to 67108863
*RST:
0
Example:
BB:MCCW:TRIG:SOUR EXT
selects an external trigger
BB:MCCW:TRIG:INH 200
sets a restart inhibit for 200 samples following a trigger event.
[:SOURce<hw>]:BB:MCCW:TRIGger:RMODe?
Queries the current status of signal generation for all trigger modes with Multi Carrier
CW on.
Return values:
<RMode>
STOP | RUN
RUN
The signal is generated. A trigger event occurred in the triggered
mode.
STOP
The signal is not generated. A trigger event did not occur in the
triggered modes, or signal generation was stopped by the com-
mand
BB:MCCW:TRIG:ARM:EXECute
(armed trigger modes
only).
Example:
SOURBB:MCCW:TRIG:SOUR EXT
sets external triggering
SOURBB:MCCW:TRIG:MODE ARET
selects the Armed_Retrigger mode
SOURBB:MCCW:TRIG:RMOD?
queries the current status of signal generation.
Response: RUN
the signal is generated, an external trigger was executed.
Usage:
Query only
Manual operation:
See
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...